+86 139 2552 1330 [email protected] Dongguan, Guangdong, China
Engineering response within 2 working days
Specification · 10 mm stroke and above

Long Stroke Solenoids

Stroke decides the family. Past about 12 mm, only a tubular frame keeps a useful force at the end of the travel.

Long stroke tubular solenoid, T4577 series
Long stroke tubular solenoid, T4577 series

A solenoid's force collapses as the air gap opens. At 2 mm the drop is modest; at 20 mm only a small fraction of the closed-gap force remains. Long stroke is therefore a structural requirement rather than a winding choice: the magnetic circuit has to be long enough, and the plunger has to be guided over its whole travel.

Tubular solenoids handle this range best because the cylindrical housing closes the flux path around the coil and the plunger runs inside a bore, so the working gap stays radial and the force stays predictable. Open-frame parts reach 10 mm to 25 mm in their long-stroke versions. Beyond that the usual answer is a longer tubular body, or a different mechanism — a motor and screw, or a lever.

10–90 mm, frame dependent
Stroke
13–64 mm
Body diameter
5–500 N
Force at working gap
front flange / threaded body
Mounting
spring, gravity or driven
Return

What this specification changes

Read the curve, not the headline

Force-stroke curves exist for a reason: the useful figure is the value at your working gap. Ask for the curve at your supply voltage and your duty cycle.

Side load kills stroke

A long plunger is a cantilever. Any side load raises friction in the bore and can jam the part part-way. Guide the load, not the plunger, or couple through a clevis.

The return spring subtracts everywhere

Spring force opposes the solenoid across the whole travel and sets the reset speed. Too stiff and the part stalls part-way; too soft and it will not reset against friction and gravity.

Stroke costs force and copper

Doubling the stroke at the same force needs a longer magnetic circuit and more copper, so the frame grows in both length and diameter. That is why long-stroke parts look oversized next to short-stroke ones.

Tell us the load at the end of the stroke, not at the start. A mechanism that is easy to move when closed can stall at full extension, which is exactly where the force is lowest.

Models that meet this specification

ModelConstructionStrokeForceVoltage
T1540L/S 15 mm Tubular Solenoid, 40 mm Body 0–10 mm (curve range) on drawing to order
T2530L/S 25 mm Tubular Solenoid, 30 mm Body 0–12 mm (curve range) on drawing to order
T6490L/S 64 mm Tubular Solenoid, 90 mm Body 0–12 mm (curve range) on drawing to order
T4577L/S Tubular T4577L/S — on drawing to order
U1253L/S Compact Open-Frame Push-Pull Solenoid up to 10 mm (curve range) on drawing Custom at order (typ. 12 / 24 V DC)

Values are catalogue figures at the stated duty cycle. The force that matters is the force at your working gap — request the curve for the model you shortlist.

Where this specification is used

Industrial Automation & MachineryMedical, Retail & Self-Service EquipmentAgriculture & Special Equipment

Questions buyers ask

What is the longest stroke available?

The longest bodies in the range are specified for travels towards 90 mm, but force at that gap is a small fraction of the closed-gap figure — the load has to be light or counter-balanced. For 10–12 mm, the T1540 and T2530 are the standard answers.

Why is the force so low at full stroke?

Magnetic force falls roughly with the square of the gap in the working region. A part that holds 200 N closed may hold 30 N at 10 mm. This is physics, not a manufacturing shortfall, and it is why the curve is published.

Can I add a linkage to extend the stroke?

Yes, but a linkage multiplies stroke and divides force, and adds friction and lost motion. If the mechanism needs 40 mm, it is usually cheaper to use the right frame than to amplify a short one.

How do I stop the plunger hammering at the end of stroke?

Fit a resilient stop or a damper. Impact at the end of travel is what wears the bore and work-hardens the plunger, and it is also the main source of noise.

Related reading

Have a drawing, a sample, or just a stroke and a force?

Send it over. An engineer reviews every enquiry and replies with a feasible concept, not a brochure.