The tests behind the numbers

Every figure on a datasheet should have a test method, a sample size and a condition behind it. This page lists what we measure and how often.

Test schedule

TestMethodFrequency
Force–strokeLoad cell sweep across the working stroke, at rated voltage and stated temperatureSampled per lot
Dielectric withstandHipot between coil and frame at specified voltage and duration100%
Insulation resistanceMegohm test at 500 V DC100%
Coil resistanceFour-wire measurement against the drawing tolerance100%
Temperature riseThermocouple or resistance method at rated duty until equilibriumType test / sampled
Cycle lifeRepeated actuation under stated load with periodic force checksType test / project
Acoustic noiseSound pressure at 1 m in a defined enclosureProject specific
Salt spray / humidityCorrosion and insulation behaviour in the specified environmentOn request

Frequency is stated per the standard build. Project specific requirements can be added to the control plan.

Reading a force figure correctly

A force number means nothing without three conditions: the stroke at which it was measured, the ambient temperature, and the duty cycle. A cold coil at 0.5 mm gap can show 40% more force than the same coil warm at 6 mm.

We state those three conditions on every datasheet. If a supplier does not, the number cannot be compared with anything — including their own other numbers.

Certification

ISO 9001 covers the quality management system. Product-level compliance — CE, RoHS, UL where applicable — depends on the part and the market. Certificates with numbers are issued against a specific part number rather than the company in general, and we will send the current revision for the part you are buying.

CE conformity certificate, SGS audited
CE conformity certificate, SGS audited
ISO 9001 quality management system certificate
ISO 9001 quality management system certificate
High-tech enterprise certification
High-tech enterprise certification
Utility model patent certificate
Utility model patent certificate
National patent certificate
National patent certificate
Third-party verified supplier assessment
Third-party verified supplier assessment

Full-size certificate scans with registration numbers are available on request.

Ask for the certificate number. A logo on a website is not a certification. Any supplier should be able to send the actual document with a valid number and an issuing body you can check.

The technical evidence pack

Every quotation and every shipped lot can be supported by five documents. Ask for them from any supplier — including us — before the purchase order:

  • Force-stroke curve of the actual frame and winding, at your voltage and duty cycle — not a single headline force figure.
  • Duty-cycle ladder: the permitted wattage and ON time at 100, 50, 25 and 10 % ED, with the coil temperature the rating assumes.
  • Cycle-test report with your stroke, load and duty stated — the method section names the fixtures, so the number can be reproduced.
  • Material and component specifications: wire gauge and insulation class, magnet grade, housing and seal materials, stated per part number.
  • Per-lot records: coil resistance (with measurement temperature) and force at a stated gap, traceable by batch for every shipment.

Documented development projects with this evidence attached are in the case studies; the factory behind the documents is described on the manufacturing page.