+86 139 2552 1330 [email protected] Dongguan, Guangdong, China
Engineering response within 2 working days
Specification · 24 V DC

24V DC Solenoids

Twice the voltage, half the current for the same wattage — which changes the wire, the driver and the cable run, but not the force.

24 V DC linear solenoid actuator
24 V DC linear solenoid actuator

Twenty-four volts is the standard control voltage in industrial cabinets, the working rail on trucks, trailers and construction equipment, and the usual choice when a solenoid sits at the end of a long cable. For the same coil wattage the current is half that of a 12 V part, so resistive loss in the cable and in the switch drops by a factor of four.

The mechanics do not change. A 24 V coil on a given frame produces the same force as the 12 V version of that frame, because the magnetic circuit and the ampere-turns are the same. What changes is the wire: thinner gauge, more turns, and a different termination and insulation requirement. The frames below can all be supplied with a 24 V winding; several ship that way as standard.

24 V DC nominal
Coil voltage
half the 12 V value at equal wattage
Current
4–12 mm
Stroke
8–120 N
Holding force
10–100 % ED
Duty cycle

What this specification changes

Cable drop is why 24 V exists

Five amps through 10 m of 0.75 mm² cable loses about 2.3 V in the run. The same power at 24 V draws 2.5 A and loses about 1.2 V, so the coil at the far end still sees a usable voltage while the 12 V part is below its pull-in threshold.

A PLC output is not a coil driver

A 24 V transistor output is typically rated 0.5 A and has no suppression. A 12 W coil needs 0.5 A at 24 V before any inrush margin. Use an interposing relay or a dedicated driver with a flyback diode.

Same frame, different winding

Coil power is set by the winding, not by the supply. The U1564L/S runs 13 W continuously or 130 W at 10 % ED; both are available at 24 V, and the choice is a duty-cycle decision rather than an electrical one.

AC and DC are not interchangeable

A 24 V AC supply on a DC coil gives no steady holding force and will overheat within minutes. If the rail is AC, rectify and smooth it, or specify an AC frame — the lamination stack is different.

A 24 V coil is not a universal upgrade. At the same wattage it draws half the current, but the thinner wire has less copper to absorb heat — check the duty-cycle ladder for the 24 V winding specifically.

Models that meet this specification

ModelConstructionStrokeForceVoltage
U1253L/S Compact Open-Frame Push-Pull Solenoid up to 10 mm (curve range) on drawing Custom at order (typ. 12 / 24 V DC)
U1564L/S Open-frame U1564L/S — on drawing to order
T2070L/S Tubular T2070L/S — on drawing to order
U2244L/S Open-frame U2244L/S — on drawing to order
KS1564L/S Bi-stable latching KS1564L/S — 1 k gf to order

Values are catalogue figures at the stated duty cycle. The force that matters is the force at your working gap — request the curve for the model you shortlist.

Where this specification is used

Industrial Automation & MachineryAutomotive & EV ChargingSmart Lockers & Vending Machines

Questions buyers ask

Does a 24 V solenoid use less power than a 12 V one?

No. Wattage is a design choice, not a consequence of voltage. At the same wattage a 24 V coil draws half the current, which reduces cable loss but does not reduce the power the coil has to dissipate.

Can a 24 V solenoid connect directly to a PLC output?

Check the output rating. A typical transistor output is 0.5 A; a 12 W coil at 24 V uses all of it, leaving nothing for inrush. An interposing relay with a suppression diode is the safer arrangement.

What is the coil resistance of a 24 V solenoid?

Resistance follows V²/P. A 12 W coil at 24 V is about 48 Ω cold. Copper resistance rises roughly 0.4 % per °C, so a coil at 100 °C measures noticeably higher.

Do I need a flyback diode?

For any DC coil switched by a semiconductor, yes — it protects the driver from the inductive kick. A plain diode slows release; a diode plus zener, or an RC network, releases faster at the cost of a higher peak voltage.

Related reading

Have a drawing, a sample, or just a stroke and a force?

Send it over. An engineer reviews every enquiry and replies with a feasible concept, not a brochure.