+86 139 2552 1330 [email protected] Dongguan, Guangdong, China
Engineering response within 2 working days
Solenoid Locks

X1010L — Cabinet Lock Solenoid, 5 V

Low-voltage sucker-type lock solenoid for smart cabinet and locker doors.

Solenoid for door lock, actual product
X1010L · product photo

Key parameters

TypeSucker / holding
Stroke3 mm
Holding forceup to 10 N
Coil voltage5 V DC
Duty cyclePulse, 100 ms max
Mounting2 × M3
Request a Sample Ask a Question
Reading these figures. Force values apply at the stroke stated, at 20 °C ambient, with the coil at rated voltage after thermal stabilisation. A figure quoted without those conditions is not comparable to another supplier's figure.

What this part is

A solenoid lock or lock actuator: the solenoid drives a bolt mechanism directly, or ships integrated as a tested assembly of solenoid, bolt and housing. Latching builds hold the state with zero current; fail position and mechanical override are design decisions stated in the drawing.

The X1010L is the Cabinet Lock Solenoid, 5 V in this family: stroke 3 mm, force up to 10 N at the working gap, wound for 5 V DC. Typical duty is in the applications listed below; the parameters table carries the full measured spec.

Force versus stroke

Force falls as the air gap opens. The curve below is typical for this frame size; the actual curve for your part number is measured on the test bench and supplied with the sample.

Force versus stroke curve Stroke (mm) Force (N) 24 V DC 12 V DC

Drawings and downloads

Drawings are issued against a confirmed part number. Request the current revision before designing the mating interface.

Used in

Smart Lockers & Vending MachinesSmart Locks & Access Control

Specification views

12V Latching SolenoidLow Power SolenoidHolding ElectromagnetDC ElectromagnetSolenoid Door LockCabinet LockLocker Lock

Other models in this family

Customisation range

Bolt throw, housing integration, open-feedback (reed/optical), fail position and mechanical override are engineered per cabinet; windings follow the rail from 5 V logic-side to 24 V industrial at the worst-case end-of-harness voltage.

Custom design process

Factory and testing

Lock assemblies ship with cycle tests at your bolt load and stroke, noise measurement at temperature extremes (a shipped automotive programme measured under 50 dB at -40 C), and shock tests against slammed-door loads. Assembly and test in Qingxi, Dongguan.

Manufacturing Quality & Testing

Selection FAQ — X1010L

Solenoid only, or complete lock assembly?

Both are supplied. The bare solenoid suits an established mechanism; the tested assembly removes the integration tolerance stack and ships with mechanism-level cycle and shock data.

What happens when power is lost?

A design decision, not a property of the solenoid: fail-secure holds locked, fail-safe releases, latching builds hold wherever they were. Unattended cabinets are fail-secure with a mechanical override.

What holding force does the lock need?

Enough to seat the bolt against preload at the end of the stroke, with latch force two to three times the slammed-door shock load - the static force alone under-specifies it.

Need this in a different stroke or coil voltage?

Most parameters on this model are adjustable without new tooling. Send the requirement and we will confirm feasibility.