+86 139 2552 1330 [email protected] Dongguan, Guangdong, China
Engineering response within 2 working days
Latching Solenoids

X40180 — Square Latching Solenoid

Permanent-magnet latching unit that holds its position with the coil de-energised.

Latching solenoid, KS series
X40180 · product photo

Key parameters

TypeLatching, square frame
Stroke4 mm
Holding forceup to 40 N
Pulse width30–100 ms
Coil voltage6 / 12 V DC
Holding current0 A
Request a Sample Ask a Question
Reading these figures. Force values apply at the stroke stated, at 20 °C ambient, with the coil at rated voltage after thermal stabilisation. A figure quoted without those conditions is not comparable to another supplier's figure.

What this part is

A latching solenoid: a permanent magnet holds the plunger at the end of its travel, so a short pulse moves it and the position is held with zero current. Bi-stable versions reverse pulse polarity between states; self-holding versions pair the magnet with a mechanical bias.

The X40180 is the Square Latching Solenoid in this family: stroke 4 mm, force up to 40 N at the working gap, wound for 6 / 12 V DC. Typical duty is in the applications listed below; the parameters table carries the full measured spec.

Force versus stroke

Force falls as the air gap opens. The curve below is typical for this frame size; the actual curve for your part number is measured on the test bench and supplied with the sample.

Force versus stroke curve Stroke (mm) Force (N) 24 V DC 12 V DC

Customisation range

Pulse ratings, holding force, plunger end form and terminations are built to order; winding follows the drive scheme (H-bridge reversal or single-polarity with spring). Mechanical release integration and lead exit options are quoted from the housing drawing.

Custom design process

Factory and testing

Pulse-data testing is part of every build: maximum ON time at your duty, holding force with the coil off, and cycle tests at stated pulse width. Per-lot coil resistance records trace every shipment. Wound, assembled and tested in Qingxi, Dongguan.

Manufacturing Quality & Testing

Selection FAQ — X40180

How much energy does one operation use?

Pulse energy only: wattage times pulse width - a 5.76 W coil over 100 ms is about 0.58 J. Between operations the coil is off and the magnet holds.

Can it hold under vibration and shock?

Yes within the holding force against the shock load. Specify two to three times the calculated worst-case load rather than the static figure, and ask for the shock test.

Single-polarity drive or H-bridge?

Depends on the build: bi-stable parts need polarity reversal between states; single-direction latching parts with a mechanical bias use one polarity and a spring. Decide the drive before choosing the coil.

Need this in a different stroke or coil voltage?

Most parameters on this model are adjustable without new tooling. Send the requirement and we will confirm feasibility.