Tubular T1340L/S from the Cixin product catalog. Duty-cycle ladder and dimensions per catalog; dimensioned drawing available on request.
| Type | Tubular, catalog design |
|---|---|
| Power @ 100 / 50 / 25 / 10% ED | 2.4 / 4.8 / 9.6 / 24 W (20 °C) |
| Max ON time @ 50 / 25 / 10% ED | 50 / 18 / 3 s |
A tubular solenoid: a cylindrical housing that closes the magnetic circuit around the coil and guides the plunger inside a bore. The highest force density of the standard constructions, with usable force at longer strokes.
The T1340L/S is the Tubular T1340L/S in this family: stroke within its rated range, force in its rated class at the working gap, wound for the standard range. Typical duty is in the applications listed below; the parameters table carries the full measured spec.
Force falls as the air gap opens. The curve below is typical for this frame size; the actual curve for your part number is measured on the test bench and supplied with the sample.
Drawings are issued against a confirmed part number. Request the current revision before designing the mating interface.
Winding (5-48 V), front-flange or threaded-body mounting, plunger end form, sealing/potting and lead exit are built to order. Body diameters are fixed tooling; stroke variants within the frame range are quoted per project.
Custom design processForce-stroke curves are measured on the bench at stated gaps and supplied with the sample - the curve on this page is typical, not the shipped data. Winding is in-house with per-lot resistance records; cycle rigs run at stated load and stroke. Qingxi, Dongguan.
Magnetic force falls roughly with the square of the gap. A part holding 200 N closed may hold 30 N at 10 mm - physics, not a shortfall, which is why the curve is published and must be read at your working gap.
Yes, at some continuous-wattage cost on small frames - potting changes the thermal path. State the environment at enquiry so the coil is rated for it.
Front flange or threaded body, by frame. Clamping a thin-walled tube out of round adds friction and costs force - use a clamp band on a reinforced section or pot it in.
Most parameters on this model are adjustable without new tooling. Send the requirement and we will confirm feasibility.