Self-holding KY0730L/S from the Cixin product catalog. Duty-cycle ladder and dimensions per catalog; dimensioned drawing available on request.
| Type | Self-holding, catalog design |
|---|---|
| Power @ 100 / 50 / 25 / 10% ED | 3.4 / 6.8 / 13.6 / 34 W (20 °C) |
| Max ON time @ 50 / 25 / 10% ED | 100 / 36 / 7 s |
A latching solenoid: a permanent magnet holds the plunger at the end of its travel, so a short pulse moves it and the position is held with zero current. Bi-stable versions reverse pulse polarity between states; self-holding versions pair the magnet with a mechanical bias.
The KY0730L/S is the Self-holding KY0730L/S in this family: stroke within its rated range, force in its rated class at the working gap, wound for the standard range. Typical duty is in the applications listed below; the parameters table carries the full measured spec.
Force falls as the air gap opens. The curve below is typical for this frame size; the actual curve for your part number is measured on the test bench and supplied with the sample.
Drawings are issued against a confirmed part number. Request the current revision before designing the mating interface.
Pulse ratings, holding force, plunger end form and terminations are built to order; winding follows the drive scheme (H-bridge reversal or single-polarity with spring). Mechanical release integration and lead exit options are quoted from the housing drawing.
Custom design processPulse-data testing is part of every build: maximum ON time at your duty, holding force with the coil off, and cycle tests at stated pulse width. Per-lot coil resistance records trace every shipment. Wound, assembled and tested in Qingxi, Dongguan.
Pulse energy only: wattage times pulse width - a 5.76 W coil over 100 ms is about 0.58 J. Between operations the coil is off and the magnet holds.
Yes within the holding force against the shock load. Specify two to three times the calculated worst-case load rather than the static figure, and ask for the shock test.
Depends on the build: bi-stable parts need polarity reversal between states; single-direction latching parts with a mechanical bias use one polarity and a spring. Decide the drive before choosing the coil.
Most parameters on this model are adjustable without new tooling. Send the requirement and we will confirm feasibility.