Push-pull guide

How to Select a Push-Pull Solenoid

A selection method for the push-pull family: direction, stroke, force at the working gap, frame construction, coil wattage ladder and duty cycle.

Updated 2026-11-23 · 9 min read · Written and reviewed by the Cixin engineering team, Dongguan

12 V open-frame push-pull solenoid used in a selection example
The U0835 frame: rectangular, open coil, available as pull or push.

Start with direction: push, pull, or either

Push-pull is the most searched solenoid family, and the search term hides the first decision. A push-pull solenoid is not one part that pushes and pulls on command. It is a frame built in two versions: the L version pulls the plunger in when energised, and the S version pushes it out. The suffix on every part number here — U0835L, U0835S — is the direction, not an option.

Which one you need depends on where the load sits. A latch bolt that must retract into the body is a pull. A dispensing gate that must kick outward is a push. If a spring returns the mechanism, the solenoid only ever works in one direction, and the spring does the other — which is usually the cheaper and quieter arrangement. If the mechanism must move both ways electrically, you need either two coils or a latching type, and this family is not the answer.

Stroke first, then force at the end of it

The push-pull range here runs from 2 mm to 25 mm of stroke and from 2 N to 120 N of holding force, but no single part covers both ends. Force falls steeply as the air gap opens: a part that holds 30 N at the closed position may deliver a third of that at 8 mm. This is the single most common selection error — matching the headline force number to the load and ignoring where along the stroke the load actually sits.

So fix the stroke first, and treat the force requirement as a force at that stroke. If the mechanism stalls halfway, the gap between the rated figure and the working-gap figure is the reason. The article on force versus stroke explains the curve and how to read one; the model pages publish the curve range for each frame.

Open frame, enclosed, or rectangular

Three constructions share this family. Open-frame parts — the U0316 to U30120 series — are the cheapest and the easiest to mount, and they dissipate heat well because the coil is exposed. They are unprotected: dust, moisture and finger contact are the machine builder's problem. Sealed parts such as the U0876 carry an IP54 rating for automotive and outdoor use, at the cost of some continuous wattage. Rectangular enclosed parts such as the U0835 sit between the two, with a defined mounting face and a protected coil.

Choose by environment first: if the part lives inside a sealed enclosure of its own, an open frame is usually right. If it breathes the same air as the user, seal it.

The coil follows the supply

Voltage is a winding choice, not a frame property. The same body is wound for 6 V, 12 V or 24 V DC, and the wattage ladder changes with the winding, not with the supply. The U1253L/S illustrates the ladder: 3.6 W continuous at 100 % ED, 7.2 W at 50 %, 14.4 W at 25 % and 36 W at 10 %. Higher wattage means more force — for less time. If your mechanism only needs the force for a hundred milliseconds, the 10 % winding gives you ten times the continuous force in the same frame.

Current draw is wattage divided by voltage, and the driver has to be sized for the cold-coil figure. A 12 W coil at 12 V draws about 1 A. Our page on 12 V push-pull solenoids lists the models that ship with a 12 V winding and the numbers that matter at that voltage.

Duty cycle and life

Duty cycle decides the coil, and the coil decides whether the part survives. A part run past its maximum ON time does not fail immediately — it loses force as it heats, and then the insulation ages. Most field failures in this family are thermal, not mechanical. The duty cycle guide covers the arithmetic; the practical version is: state how long the coil is on per cycle and how often it cycles, and take the coil rating from that, not from the peak force.

Life is set by the stop, the spring and the side load, in roughly that order. Open-frame push-pull parts routinely reach hundreds of thousands of cycles when the plunger is not side-loaded and the stop is resilient. A bent plunger from a side load is the most common premature failure we see.

Validate with the real mechanism

A sample costs days; a wrong frame costs a redesign. Send the stroke, the force at that stroke, the duty cycle and the supply, and ask for the force-stroke curve of the shortlisted frame at your voltage. Then test the sample in the mechanism, not on a bench: spring preload, friction and misalignment all reduce the force the solenoid actually has to give, and only the assembly can show by how much.

If nothing in the catalogue fits — a stroke between two frames, an envelope that does not match, a duty cycle the ladder cannot cover — that is a custom winding or a custom frame, and the custom design process starts from the same four numbers.

Frequently asked questions

Can a push-pull solenoid really push and pull?

Not on command. The frame is built as a pull version (L) or a push version (S); the direction is set by the plunger end and the stop, not by the polarity of the supply. Bi-directional motion needs two coils, a latching type, or a spring doing one direction.

Can I buy the same model in 12 V and 24 V?

Yes. Voltage is a winding on the same frame, so the mechanics, mounting and stroke are identical; only the wire gauge, current and wattage ladder change. State the supply voltage at enquiry and the coil is wound for it.

My prototype has less force than the datasheet. Why?

Usually one of three things: the load sits at a larger air gap than the rating point, the supply sags under inrush, or the coil is hot and the resistance has risen. Measure the voltage at the coil terminals during the pulse and the temperature of the coil before blaming the part.

How long can a push-pull solenoid stay energised?

Only within its duty-cycle rating. Each frame publishes a maximum ON time per ED step — for example 100 s at 50 % ED and 7 s at 10 % ED on the U1253L/S. Beyond that the coil overheats and the force collapses before the insulation is damaged.