Open-frame U0420L/S from the Cixin product catalog. Duty-cycle ladder and dimensions per catalog; dimensioned drawing available on request.
| Type | Open-frame, catalog design |
|---|---|
| Power @ 100 / 50 / 25 / 10% ED | 1.2 / 2.4 / 4.8 / 12 W (20 °C) |
| Max ON time @ 50 / 25 / 10% ED | 18 / 30 / 50 s |
An open-frame or enclosed push-pull solenoid: a rectangular frame with an exposed or protected coil, built as a pull (L) or push (S) version. Energise the coil and the plunger moves in one direction; a spring or the mechanism returns it.
The U0420L/S is the Open-frame U0420L/S in this family: stroke within its rated range, force in its rated class at the working gap, wound for the standard range. Typical duty is in the applications listed below; the parameters table carries the full measured spec.
Force falls as the air gap opens. The curve below is typical for this frame size; the actual curve for your part number is measured on the test bench and supplied with the sample.
Drawings are issued against a confirmed part number. Request the current revision before designing the mating interface.
Winding (5-48 V), plunger end form, return spring, lead exit, mounting flange and sealing are all built to order on this frame; prototypes from one piece, usually without new tooling. Stroke is fixed by the frame geometry - other strokes are a different frame size.
Custom design processWound and assembled in Qingxi, Dongguan: coil winding with per-lot resistance records, force-stroke testing at stated gaps, and cycle rigs running at your load. Samples ship with the measured curve, not the catalogue curve. See manufacturing and quality pages for the process and document set.
Direction. The L version pulls the plunger into the coil when energised; the S version pushes it out. It is a mechanical build difference - plunger end and stop - not a wiring polarity option.
Yes. The frame mechanics do not change; the winding changes wire gauge, current and the wattage ladder. State the supply voltage and duty cycle and the coil is wound for it.
Hundreds of thousands of cycles when the plunger is not side-loaded and the stop is resilient. Life is set by the stop, spring and side load in that order - ask for the cycle-test report at your load and stroke.
Most parameters on this model are adjustable without new tooling. Send the requirement and we will confirm feasibility.